PT100 4-20mA Hart temperature transmitter

PT100 4-20mA Hart Temperature Transmitter Overview:PT100 4-20mA hart temperature transmitter, as a temperature measurement sensor, is usually used together with temperature transducer, regulator and display instrument to form a process control system for direct measurement or control of the temperature of liquid, vapor and

Featured Products

PT100 4-20mA Hart Temperature Transmitter

PT100 4-20mA Hart Temperature Transmitter Overview:

PT100 4-20mA hart temperature transmitter, as a temperature measurement sensor, is usually used together with temperature transducer, regulator and display instrument to form a process control system for direct measurement or control of the temperature of liquid, vapor and gas media as well as solid surface within -200ºC~500ºC in various production processes. The thermal resistor measures temperature by using the characteristic that the resistance itself changes with the change of temperature of substance. When temperature gradient exists in the measured medium, the temperature measured is the average temperature of the medium where temperature-sensing element is located. Although the appearance of all thermal resistors varies widely, their basic structure is roughly similar, generally including such major components as temperature-sensing element, insulation casing, protective tube and junction box. 

PT100 4-20mA Hart Temperature Transmitter Features:
* German temperature sensor, with high temperature measurement accuracy.
* Simple installation and a variety of temperature ranges optional.
* Gas-liquid dual-purpose, any medium compatible with 316L. 
* German thin-film resistive element, with rapid thermal response speed and reliable and stable performance.
* Good long-term stability, low energy consumption and small size.
* Compression spring-type temperature sensor, with good vibration resistance.
* Automatic compensation of cold end temperature, using non-linear correction circuit.
PT100 4-20mA Hart Temperature Transmitter
PT100 4-20mA Hart Temperature Transmitter Application:
* Piping and ventilation system
* Hydraulic and pneumatic system 
* Cooling system and heating system
* Water supply and hot water system
* Air conditioning system

PT100 4-20mA Hart Temperature Transmitter Working Principle:
PT100 4-20mA hart temperature transmitter by using the characteristic that the resistance itself changes with the change of temperature of substance. When the resistance changes, the bridge passing through the temperature transducer will produce an unbalanced signal, which is converted into 4-20mA DC signal after being amplified, and then the working instrument will show the corresponding temperature value.

Technical Parameters:
Measuring range-200ºC~500ºC
Measured mediumGas or liquid compatible with 304 or 316 L stainless steel
OutputSensor (PT100); transducer (two-wire system 4-20mA+HART protocol)
Power supply10~36V DC
Overall accuracy ±0.5%FS  ;  ±0.25%FS  ; ±0.1%FS
Allowable error Graduation PT100: Grade A (±0.15+0.002 ltl); Grade B (±0.30+0.005 ltl) 
Withstand voltageTypical: 40bar (Max:300bar) 
Long-term stability±0.1%FS/ year
Response timeT=50ºC 2.3s ; T=90ºC  5.4s
Electrical protectionReverse polarity protection and optional surge voltage protection
Ambient temperature -40~+85ºC
Storage temperature -40~+125ºC
Installation mode Plug-in (insertion depth: beyond 50mm thread; can be customized)
Probe dimensionsΦ12, Φ8, Φ6 (mm), others 
Liquid-contacting material304 stainless steel, 316 stainless steel, 316L stainless steel lined PTFE
Damping Adjustable 0-32 seconds 
Protection degreeIP65;IP67
Resistance to mechanical vibration10~60HZ, 0.21mm sine wave
ARFIIEC61000-4-3, 20V/M,80~1000MHZ
Executive standardIEC584 ;IEC1515;GB/T16839-199;JB/T5582-91     

Ordering Information:
PT1004-20mA Hart Temperature Transmitter
 CodeType: Transducer (4-20mA)-B (may not be indicated as default); sensor (PT100) -P
 RangeMeasuring Range: 0~ X ºC, e.g.: 0~100ºC
 CodeOverall accuracy 
10.5%FS  (PT100-Grade B)
20.25%   (PT100- Grade A)
30.1%    (PT100- Grade A)
 CodeOutput Mode
V1PT100
A1Two-wire system 4-20mA
S1Two-wire system 4-20mA overlapped with HART protocol intelligence
 CodePressure interface 
F1M20x1.5 external thread 
F2G1/4 external thread
F0Custom (including flange, special thread)
 CodeElectrical connection mode
W1Cable type (2m shielded wire)
W2HSM Socket
W3Air plug to 2m shielded wire
 CodeOuter protective pipe diameter (insertion depth mm)
J1Φ12 outer protective pipe (insertion depth)
J2Φ8 outer protective pipe (insertion depth)
J3Φ6 outer protective pipe (insertion depth)
J4 Other outer protective pipes (insertion depth)
 CodeAdditional selections
X304 steel pipe (may not be indicated)
Y316L steel pipe
F316L stainless steel + lined PTFE
EIntrinsically safe explosion - proof Ex iaIICT6
PT100(0~100ºC)  -1  -S1  -F1  -W3  -J1(50mm)  -Y   4-20mA Hart Temperature Transmitter

Tips for Type Selection
* The measured medium shall be compatible with the material contacting with the product.
* Please contact us for other special requirements and clearly indicate them in the order.

PT100 4-20mA Hart Temperature TransmitterPT100 4-20mA Hart Temperature Transmitter

About Jiucheng
PT100 4-20mA Hart Temperature Transmitter

Qualification and Certificate:
PT100 4-20mA Hart Temperature Transmitter

PT100 4-20mA Hart Temperature Transmitter


Product Packaging:
We choose cartons and protective pads that can be recycled. This will maximize the protection of our products from damage during transportation.
PT100 4-20mA Hart Temperature Transmitter

Product Transportation:
We only choose the global express service providers. We will deliver the goods to you at the most efficient speed.
PT100 4-20mA Hart Temperature Transmitter
 

Contact us